Auto zero tracking, communications zero command, and remote zero all use the auto zero parameter tolerance. The remote zero and auto zero tracking would fail to zero the additional 2 pounds on the scale. If you zero out 4 pounds gross using the zero button on the front display, and had the auto zero tolerance set for 2 lb. The NET weight has no limit and is set to zero using the tare function.Īs an Example: With a zero tolerance setting of 5 lb. The amount of zero is limited by the auto zero parameter and that zero limit is an accumulated amount of GROSS weight offset from the last calibration. The remote zero option is active with contact between the DIS terminal and ground terminal of the remote function terminal strip. Apply power and wait for the boot cycle to complete. Power down the controller, remover the old SMM and install the new SMM. With all the original setup parameters recorded. There should have been a addendum included that says how to install the SMM with power OFF. Installing the SMM under power will erase the TAG2 option code. You will need to re-enter all this information and re-calibrate the scale after the upgrade. Record any communications information and all the parameters from the old SMM using the front display to access the information. When installing a new Secure Memory Module (SMM) the instrument should treated as a new installation.